The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.
The 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive™ video calls.
With True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.
Other useful capabilities:
Compatible with optional TPAK magnetic hanging strap
Comes with soft carrying case, batteries, and three-year warranty
Measures capacitance to 1000 µF
Features CAT III 1000 V, CAT IV 600 V safety rating
Provides True-RMS voltage and current measurements to accurately measure non-linear signals
Includes Min/Max/Avg and inrush recording to capture variations automatically
Runs on two AA alkaline batteries
AC Current via Jaw:
•Range: 600.0 A
•Resolution: 0.1 A
•Accuracy: 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100-500 Hz)
•Crest Factor (50 Hz/60 Hz): 2.5 @ 600 A
•Add 2% for C.F. >2
AC Current via Flexible Current Probe:
•Range: 2500 A
•Resolution: 0.1 A (≤ 600 A), 1 A (≤ 2500 A)
•Accuracy: 3% ±5 digits (5 – 500 Hz)
•Crest Factor (50/60Hz): 2.5 at 1400 A, 1.42 at 2500 A
•Add 2% for C.F. > 2
•Position Sensitivity:
-Flexible current probe
i2500-10 Flex: Distance from Optimum A: 0.5 in (12.7 mm), B: 0.8 in (20.3 mm), C: 1.4 in (35.6 mm), Error: ±0.5% to ±2.0%
i2500-18 Flex: Distance from Optimum A: 1.4 in (35.6 mm), B: 2.0 in (50.8 mm), C: 2.5 in (63.5 mm), Error: ±0.5% to ±2.0%
•Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current:
•Range: 600.0 A
•Resolution: 0.1 A
•Accuracy: 2% ±5 digits
AC Voltage:
•Range: 1000 V
•Resolution: 0.1 V (≤600.0 V), 1 V (≤1000 V)
•Accuracy: 1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage:
•Range: 1000 V
•Resolution: 0.1 V (≤600.0 V), 1 V (≤1000 V)
•Accuracy: 1% ±5 digits
mV dc:
•Range: 500.0 mV
•Resolution: 0.1 mV
•Accuracy: 1% ±5 digits
Resistance:
•Range: 6000 Ω
•Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω)
•Accuracy: 1% ±5 digits
Capacitance:
•Range: 1000 μF
•Resolution: 0.1 μF (≤ 100 μF), 1 μ F (≤ 1000 μF)
•Accuracy: 1% ±4 digits
Mechanical Specifications:
•Maximum voltage between any terminal and earth ground: 1000 V
•Batteries: 2 AA, NEDA 15A, IEC LR6
•Operating temperature: -10 °C to +50 °C
•Storage temperature: -40 °C to +60 °C
•Operating humidity – non-condensing (< 10°C):
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)