FLUKE 117C

SKU: TMMI0004 Brand:
SKU: TMMI0004 Category: Brand:

177,14 

Type ETA Cost
Inside UAE 2 - 3 Days 22 AED
Pickup 1 Day Free
International 4 - 7 Days 100 AED
  • International Delivery

International

4 - 7 Days

Will be calculated at checkout

  • Self Pickup

Pickup

Sameday

Free

  • Inside UAE Delivery

Inside UAE

2 - 3 Days

AED 29/-

Payment Methods:

 VoltAlert technology for non-contact voltage detection AutoVolt automatic AC/DC voltage selection
Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True RMS for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) for hands free operation CAT III 600 V safety rated
Specifications: Maximum voltage between any terminal and earth ground: 600
V Surge protection: 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for
A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display:
Digital: 6, 000 counts, updates 4 per second
Bar graph: 33 segments, updates 32 per second
Operating Temperature: -10 °C to + 50 °C
Storage Temperature: -40 °C to + 60 °C
Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life: 400 hours typical, without backlight Accuracy Specifications DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5 % + 2 DC volts
Range/Resolution: 6.000 V / 0.001
V Range/Resolution: 60.00 V / 0.01
V Range/Resolution: 600.00 V / 0.1
V Accuracy: ± ([% of reading] + [counts]): 0.5 % + 2 Auto volts
Range: 600.0
V Resolution: 0.1
V Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001
V Range/Resolution: 60.00 V / 0.01
V Range/Resolution: 600.0 V / 0.1
V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range: 600
O Resolution: 1
O Accuracy: Beeper on less than 20 O, off more than 250 O; detects opens or shorts of 500 µs or longer.
Ohms Range/Resolution: 600.0 O / 0.1
O Range/Resolution: 6.000 k O / 0.001 k
O Range/Resolution: 60.00 k O / 0.01 k
O Range/Resolution: 600.0 k O / 0.1 k
O Range/Resolution: 6.000 M O / 0.001
M O Accuracy: 0.9 % + 1
Range/Resolution: 40.00 M O / 0.01
M O Accuracy: 5 % + 2
Diode Test Range/Resolution: 2.000 V / 0.001
V Accuracy: 0.9 % + 2
Capacitance Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9 % + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20% LoZ capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution: 6.000 A / 0.001
A Range/Resolution: 10.00 A / 0.01
A Accuracy: 1.5 % + 3 20 A continuous overload for 30 seconds max DC amps
Range/Resolution: 6.000 A / 0.001
A Range/Resolution: 10.00 A / 0.01
A Accuracy: 1.0 % + 3 20 A continuous overload for 30 seconds max Hz (V or A input) 2
Range/Resolution: 99.99 Hz / 0.01
Hz Range/Resolution: 999.99 Hz / 0.1
Hz Range/Resolution: 9.999 Hz / 0.001
Hz Range/Resolution: 50.00 Hz / 0.01
Hz Accuracy: 0.1 % + 2

 

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “FLUKE 117C”